Communications Processors  Manufacturers, Traders, Suppliers

7 companies for Communications Processors ✓ B2B manufacturers, distributors & suppliers from 2 countries ✓ With special service for fast information and prices ✓

Filter:
Country / region Vendor type
621000 MianYang, China ODOT
Company Profile Send enquiry Go to homepage
  • MG-CANEX CANOPEN TO MODBUS TCP CONVERTER - Product Feature: MG-CANEX Protocol Converter CANopen to Modbus TCP protocol conve...
  • ODOT-PNM02 V2.0 / V2.1: MODBUS-RTU/ASCLL OR NON-STANDARD PROTOCOL TO PROFINET CONVERTER - Product Feature: ODOT-PNM02 V2.1 M...
  • ODOT-S4E2: 4 SERIAL MODBUS RTU/ASCII TO MODBUS TCP CONVERTER - Product Feature: ♦ Supports protocol conversion between Modbus-R...
  • ODOT-S2E2: 2 SERIAL MODBUS RTU/ASCII TO MODBUS TCP CONVERTER - Product Feature: ♦ Supports protocol conversion between Modbus-R...
  • ODOT-DPM01: MODBUS-RTU TO PROFIBUS-DP CONVERTER - Product Feature: ♦ Supports protocol conversion between Modbus and PROFIBUS ...
  • ODOT-S1E1 V2.0: SERIAL GATEWAY - Product Feature: This is a converter developed by Sichuan Odot Automation System Co., LTD betw...
Description

C3351 MODBUS-TCP/MODBUS-RTU PLC CONTROLLER (CODESYSV3.5)
Product Feature:
ODOT PLC C-3351 Codesys V3.5
1.Reliable, compact, easy to expansion IO, can support up to 32 I/O modules.
2. It could be applied to multiple industries and scenarios such as mechanical processing equipment, sewage treatment, textile, non-standard automation, etc.
3. Seamless communication with reliable connection. Modbus TCP Server and Modbus TCP client are supported simultaneously.
It supports Modbus RTU master or slave.
4. It is a programmable system that follows the IEC61131-3 international standard. It supports five programming languages such as ladder diagram (LD), instruction list (IL), structured text (ST), function block diagram (CFC/FBD) and Sequential Function Chart (SFC).

Technical data

Technical Parameters
Hardware Specification
System Power: Nominal 24Vdc, Range-9-36Vdc
Protection: Overcurrent Protection, Reverse Protection: YES
Power Consumption: 110mA@24Vdc
Internal BUS Supply Current: Max.2A@5VDC
Isolation: System Power to Field Power Isolation
Field Power Supply Power Supply: 22~28V(Nominal 24VDC)
Field Power Supply Current: Max. DC 8A
I/O Modules supported: 32 pcs
Wiring: Max.1.5mm²(AWG 16)
Mounting Type: 35mm Size DIN-Rail
Size: 115*51.5*75mm
Weight: 130g
Environment Specification
Operational Temperature: -40~85℃
Operational Humidity: 5%~95% RH(Condensation)
Protection Level: IP20
EtherCAT: Parameter
Protocol: EtherCAT
Process data area: Input Max.1024 Bytes, Output Max.1024 Bytes
Network Interface: 2 RJ45
Speed: 10/100Mbps, MDI/MIDX, Full-Duplex
Max.Bus Legenth: 100m
Technical Parameters
General Parameters
System power supply:22-28VDC(Nominal 24VDC)
Protection:Anti-reverse connection protection
Module consumption:70mA@24Vdc
Internal Bus supply current:Max:2.0A@5VDC
Isolation:system to site power isolation
Field power supply:22-28V(Nominal 24V)
Field supply current:Max. DC 8A
Number of supported I/O modules:32 pcs
Wiring diameter:Max.1.5mm² (AWG 16)
Way to install:35mm DIN rail
Dimension:115 * 65.5 * 75mm
Weight:120g
Environment Parameters
Operating Temperature:-30~70℃
Environment Humidity:5%~95% RH(No Condensation)
Ingress Protection Rating:IP20
Programming Specification
Programming Software:CODESYS SP17
Programming language:IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
Maximum State Tasks:5
Bit Instruction Cycle:0.21us
Word Transfer Cycle:0.39us
Floating Point Operation Cycle:0.42us
Program Memory:1MBytes
Data Storage:1MBytes
Power-down Protection Area:3KBytes
RTC:Not Supported
Maximum Expansion Module:32
Modbus Master Max Channel Numbers:10
Modbus Master Command Max Length:
Function Code 1(Read Coils):2000
Function Code 2(Read Discrete Inputs):2000
Function Code 3(Read Holding Registers):125
Function Code 4(Read Input Registers):125
Function Code 15(Write Multiple Coils):440
Function Code 16(Write Multiple Registers):27
Function Code 23(Read/Write Multiple Registers):25+25
Interface Parameters
Interface:2 * RJ45 & 1 * RS485
Network Port Baud Rate:10/100Mbps, Adaptive and full duplex
Network Protocol:Modbus TCP,the default IP of the device is 192.168.0.15
Serial Port Configuration(RS485):Supports Modbus RTU/ASCII, the baud rate is 2400~115200bps, and supports the parameter configuration of parity code and stop bit
LED indicator:6 LEDs PWR STAT RUN NET IRN IER
Link Parameters
Modbus TCP Client:Max supports for connecting 6 Modbus TCP servers
Modbus TCP Server:Max supports for 6 Modbus TCP clients connected
Modbus RTU Master:Max supports for connecting 5 slave devices
Modbus RTU Slave:Max supports for connecting 1 master device
Technical Parameters
General Parameters
System power supply:22-28VDC(Nominal 24VDC)
Protection:Anti-reverse connection protection
Module consumption:70mA@24Vdc
Internal Bus supply current:Max:2.0A@5VDC
Isolation:system to site power isolation
Field power supply:22-28V(Nominal 24V)
Field supply current:Max. DC 8A
Number of supported I/O modules:32 pcs
Wiring diameter:Max.1.5mm² (AWG 16)
Way to install:35mm DIN rail
Dimension:115 * 65.5 * 75mm
Weight:120g
Environment Parameters
Operating Temperature:-30~70℃
Environment Humidity:5%~95% RH(No Condensation)
Ingress Protection Rating:IP20
Programming Specification
Programming Software:CODESYS SP17
Programming language:IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
Maximum State Tasks:5
Bit Instruction Cycle:0.21us
Word Transfer Cycle:0.39us
Floating Point Operation Cycle:0.42us
Program Memory:1MBytes
Data Storage:1MBytes
Power-down Protection Area:3KBytes
RTC:Not Supported
Maximum Expansion Module:32
Modbus Master Max Channel Numbers:10
Modbus Master Command Max Length:
Function Code 1(Read Coils):2000
Function Code 2(Read Discrete Inputs):2000
Function Code 3(Read Holding Registers):125
Function Code 4(Read Input Registers):125
Function Code 15(Write Multiple Coils):440
Function Code 16(Write Multiple Registers):27
Function Code 23(Read/Write Multiple Registers):25+25
Interface Parameters
Interface:2 * RJ45 & 1 * RS485
Network Port Baud Rate:10/100Mbps, Adaptive and full duplex
Network Protocol:Modbus TCP,the default IP of the device is 192.168.0.15
Serial Port Configuration(RS485):Supports Modbus RTU/ASCII, the baud rate is 2400~115200bps, and supports the parameter configuration of parity code and stop bit
LED indicator:6 LEDs PWR STAT RUN NET IRN IER
Link Parameters
Modbus TCP Client:Max supports for connecting 6 Modbus TCP servers
Modbus TCP Server:Max supports for 6 Modbus TCP clients connected
Modbus RTU Master:Max supports for connecting 5 slave devices
Modbus RTU Slave:Max supports for connecting 1 master device

Areas of application

Applied for industrial automation area related for control system and data collection solutions.

Show more
91074 Herzogenaurach, Germany VIPA Gesellschaft für Visualisierung und Prozessautomatisierung mbH Manufacturer ✓ Trader ✓
Company Profile Send enquiry
  • Communications Processors
79331 Teningen, Germany FRAKO KONDENSATOREN ANLAGENBAU GmbH Manufacturer ✓ Trader ✓
Company Profile Send enquiry
  • Communications Processors
68163 Mannheim, Germany LiPPERT ADLINK Technology GmbH Manufacturer ✓ Trader ✓
Company Profile Send enquiry
  • Communications Processors
47057 Duisburg, Germany microTEC Gesellschaft für Mikrotechnologie mbH Manufacturer ✓ Trader ✓ Supplier ✓ Service provider ✓
Company Profile Send enquiry
  • Communications Processors
CONTA-CLIP Verbindungstechnik GmbH Manufacturer ✓ Service provider ✓
Company Profile Send enquiry
  • GSM-PRO 2 the Communication module - CONTA-CLIP`s GSM-PRO2 module provides a 2G/3G remote control and maintenance solution which ...
Description

CONTA-CLIP is one of Europe’s leading manufacturers of electric terminal blocks. Based in Hövelhof, Germany, the medium-sized, family-run company has been producing electric and electronic connection systems for the process and automation industries for more than 40 years. CONTA-CLIP supplies all industry sectors, focusing on railroad industries, shipbuilding, building automation, conveyor technology, machine and plant engineering and construction, instrumentation and control technology, control panel manufacturing, transformer manufacturing, and environmental technology. The company consists of three specialized branches: CONTA-CONNECT for electric connection technology, CONTA-ELECTRONICS for electronics and CONTA-CON for PCB edge connectors. Additionally, CONTA-CLIP provides services such as customizing housings and mounting rails, labeling and supplying user-specific electronic components.

Show more
Siemens Aktiengesellschaft Manufacturer ✓ Trader ✓ Supplier ✓ Service provider ✓
Company Profile Send enquiry
About us
Siemens is a global powerhouse focusing on the areas of electrification, automation and digitalization. One of the world’s largest producers of energy-efficient, resource-saving technologies, Siemens is a leading supplier of systems for power generation and transmission as well as medical diagnosis. In infrastructure and industry solutions the company plays a pioneering role.

Communications Processors - Manufacturers, Traders & Suppliers

Communications Processors
Special service for Communications Processors
Severe lack of time to search for Communications Processors? Just enter your data in the special service form.

Our consultants will find for you the best manufacturers, distributors or service providers for Communications Processors and will forward your mail request to these companies immediately.

Are you looking for Communications Processors?
Are you looking for Communications Processors. IndustryStock's product and service search engine will not only help you find relevant results for Communications Processors but also related products and services. All contact information of listed Communications Processors manufacturers, traders, suppliers and dealers are freely available to all users.

How do you rate the information on this page?
6 Reviews 92%
We use cookies and similar tools that are necessary to provide our services. This is also described in our Cookie Policy. We also use these cookies to track how users use our services (for example, by measuring website traffic) so that we can make improvements. According to EU cookie guidelines, we may store cookies on your device if they are strictly necessary for visiting this site. For all other types of cookies, we need your permission. For more information about cookies, please visit the following link.
What are cookies? Cookie settings
Accept all cookies