81 companies for Network Systems ✓ B2B manufacturers, distributors & suppliers from 7 countries ✓ With special service for fast information and prices ✓
- MG-CANEX CANOPEN TO MODBUS TCP CONVERTER - Product Feature: MG-CANEX Protocol Converter CANopen to Modbus TCP protocol conve...
- ODOT-PNM02 V2.0 / V2.1: MODBUS-RTU/ASCLL OR NON-STANDARD PROTOCOL TO PROFINET CONVERTER - Product Feature: ODOT-PNM02 V2.1 M...
- ODOT-S4E2: 4 SERIAL MODBUS RTU/ASCII TO MODBUS TCP CONVERTER - Product Feature: ♦ Supports protocol conversion between Modbus-R...
- ODOT-S2E2: 2 SERIAL MODBUS RTU/ASCII TO MODBUS TCP CONVERTER - Product Feature: ♦ Supports protocol conversion between Modbus-R...
- ODOT-DPM01: MODBUS-RTU TO PROFIBUS-DP CONVERTER - Product Feature: ♦ Supports protocol conversion between Modbus and PROFIBUS ...
- ODOT-S1E1 V2.0: SERIAL GATEWAY - Product Feature: This is a converter developed by Sichuan Odot Automation System Co., LTD betw...
C3351 MODBUS-TCP/MODBUS-RTU PLC CONTROLLER (CODESYSV3.5)
Product Feature:
ODOT PLC C-3351 Codesys V3.5
1.Reliable, compact, easy to expansion IO, can support up to 32 I/O modules.
2. It could be applied to multiple industries and scenarios such as mechanical processing equipment, sewage treatment, textile, non-standard automation, etc.
3. Seamless communication with reliable connection. Modbus TCP Server and Modbus TCP client are supported simultaneously.
It supports Modbus RTU master or slave.
4. It is a programmable system that follows the IEC61131-3 international standard. It supports five programming languages such as ladder diagram (LD), instruction list (IL), structured text (ST), function block diagram (CFC/FBD) and Sequential Function Chart (SFC).
Technical Parameters
Hardware Specification
System Power: Nominal 24Vdc, Range-9-36Vdc
Protection: Overcurrent Protection, Reverse Protection: YES
Power Consumption: 110mA@24Vdc
Internal BUS Supply Current: Max.2A@5VDC
Isolation: System Power to Field Power Isolation
Field Power Supply Power Supply: 22~28V(Nominal 24VDC)
Field Power Supply Current: Max. DC 8A
I/O Modules supported: 32 pcs
Wiring: Max.1.5mm²(AWG 16)
Mounting Type: 35mm Size DIN-Rail
Size: 115*51.5*75mm
Weight: 130g
Environment Specification
Operational Temperature: -40~85℃
Operational Humidity: 5%~95% RH(Condensation)
Protection Level: IP20
EtherCAT: Parameter
Protocol: EtherCAT
Process data area: Input Max.1024 Bytes, Output Max.1024 Bytes
Network Interface: 2 RJ45
Speed: 10/100Mbps, MDI/MIDX, Full-Duplex
Max.Bus Legenth: 100m
Technical Parameters
General Parameters
System power supply:22-28VDC(Nominal 24VDC)
Protection:Anti-reverse connection protection
Module consumption:70mA@24Vdc
Internal Bus supply current:Max:2.0A@5VDC
Isolation:system to site power isolation
Field power supply:22-28V(Nominal 24V)
Field supply current:Max. DC 8A
Number of supported I/O modules:32 pcs
Wiring diameter:Max.1.5mm² (AWG 16)
Way to install:35mm DIN rail
Dimension:115 * 65.5 * 75mm
Weight:120g
Environment Parameters
Operating Temperature:-30~70℃
Environment Humidity:5%~95% RH(No Condensation)
Ingress Protection Rating:IP20
Programming Specification
Programming Software:CODESYS SP17
Programming language:IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
Maximum State Tasks:5
Bit Instruction Cycle:0.21us
Word Transfer Cycle:0.39us
Floating Point Operation Cycle:0.42us
Program Memory:1MBytes
Data Storage:1MBytes
Power-down Protection Area:3KBytes
RTC:Not Supported
Maximum Expansion Module:32
Modbus Master Max Channel Numbers:10
Modbus Master Command Max Length:
Function Code 1(Read Coils):2000
Function Code 2(Read Discrete Inputs):2000
Function Code 3(Read Holding Registers):125
Function Code 4(Read Input Registers):125
Function Code 15(Write Multiple Coils):440
Function Code 16(Write Multiple Registers):27
Function Code 23(Read/Write Multiple Registers):25+25
Interface Parameters
Interface:2 * RJ45 & 1 * RS485
Network Port Baud Rate:10/100Mbps, Adaptive and full duplex
Network Protocol:Modbus TCP,the default IP of the device is 192.168.0.15
Serial Port Configuration(RS485):Supports Modbus RTU/ASCII, the baud rate is 2400~115200bps, and supports the parameter configuration of parity code and stop bit
LED indicator:6 LEDs PWR STAT RUN NET IRN IER
Link Parameters
Modbus TCP Client:Max supports for connecting 6 Modbus TCP servers
Modbus TCP Server:Max supports for 6 Modbus TCP clients connected
Modbus RTU Master:Max supports for connecting 5 slave devices
Modbus RTU Slave:Max supports for connecting 1 master device
Technical Parameters
General Parameters
System power supply:22-28VDC(Nominal 24VDC)
Protection:Anti-reverse connection protection
Module consumption:70mA@24Vdc
Internal Bus supply current:Max:2.0A@5VDC
Isolation:system to site power isolation
Field power supply:22-28V(Nominal 24V)
Field supply current:Max. DC 8A
Number of supported I/O modules:32 pcs
Wiring diameter:Max.1.5mm² (AWG 16)
Way to install:35mm DIN rail
Dimension:115 * 65.5 * 75mm
Weight:120g
Environment Parameters
Operating Temperature:-30~70℃
Environment Humidity:5%~95% RH(No Condensation)
Ingress Protection Rating:IP20
Programming Specification
Programming Software:CODESYS SP17
Programming language:IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
Maximum State Tasks:5
Bit Instruction Cycle:0.21us
Word Transfer Cycle:0.39us
Floating Point Operation Cycle:0.42us
Program Memory:1MBytes
Data Storage:1MBytes
Power-down Protection Area:3KBytes
RTC:Not Supported
Maximum Expansion Module:32
Modbus Master Max Channel Numbers:10
Modbus Master Command Max Length:
Function Code 1(Read Coils):2000
Function Code 2(Read Discrete Inputs):2000
Function Code 3(Read Holding Registers):125
Function Code 4(Read Input Registers):125
Function Code 15(Write Multiple Coils):440
Function Code 16(Write Multiple Registers):27
Function Code 23(Read/Write Multiple Registers):25+25
Interface Parameters
Interface:2 * RJ45 & 1 * RS485
Network Port Baud Rate:10/100Mbps, Adaptive and full duplex
Network Protocol:Modbus TCP,the default IP of the device is 192.168.0.15
Serial Port Configuration(RS485):Supports Modbus RTU/ASCII, the baud rate is 2400~115200bps, and supports the parameter configuration of parity code and stop bit
LED indicator:6 LEDs PWR STAT RUN NET IRN IER
Link Parameters
Modbus TCP Client:Max supports for connecting 6 Modbus TCP servers
Modbus TCP Server:Max supports for 6 Modbus TCP clients connected
Modbus RTU Master:Max supports for connecting 5 slave devices
Modbus RTU Slave:Max supports for connecting 1 master device
Applied for industrial automation area related for control system and data collection solutions.
- ZLWL SS2031 Industrial Wifi Serial Server - ChiLink IOT SS2031 Wifi serial server, supports a single RS232 or RS485 interface devi...
- ZLWL ZD3030 Industrial Cellular Serial DTU With Sim Card slot - ZD3030 serial to cellular IP modem is widely used as data transmis...
- ZLWL ZS5000 Dual SIM Card Wireless Industrial 4G Cellular Router - The advantage of the ZS5000 series industrial 4G routers is tha...
- ZLWL ZR2000 Outdoor Industrial 4G Cellular Lte Wireless Router with Sim card slot - The advantages of ZR2000 series 4G cellular ro...
- ZLWL ZR9000 Dual SIM Card 5G Industrial Cellular Router - The advantage of ZR9000 series industrial 5G Cellular routers is Dual SI...
Network system, the full name of network operating system, is used to represent two quite different concepts: a special operating system running on routers, network switches, and firewalls; A computer network-oriented operating system that allows multiple computers in the network to access shared files and printers, and allows sharing of data, users, groups, security, applications and other network functions.
- Network Systems | Network Technologies | Network Structure
- Network Systems | Network Technologies | Network Structure
- Network Systems | Network Technologies | Network Components
- Network Systems | Networks
- Network Systems | Data Network Technology | Computer Networks
- Network Systems | Network Technologies | Network Administration
- Network Systems | Network Technologies | Network Devices
- Network Systems | Network Management Systems | Industrial IoT
- Network Systems | Network Technologies | Data Network Technology
- Network Systems | Networks | Network Management
- Network Systems
Als ganzheitlicher IT-Dienstleister, mit Standort in Wuppertal, beraten wir klein- und mittelständische Unternehmen bei dem praktischen Einsatz moderner IT-Lösungen. Mit qualitativ anspruchsvollen Lösungen in den Bereichen IT-Infrastruktur und individueller Softwareentwicklung schaffen wir langfristige Mehrwerte für Unternehmen und Menschen. Wir implementieren maßgeschneiderte IT-Systeme und decken dabei die ganze Bandbreite von Netzwerk- und Serverstruktur, Kommunikation und Sicherheit ab. Unsere Softwareentwicklung entwickelt individuelle Unternehmenslösungen, Produktkonfiguratoren, Apps, Shopsysteme und moderne Webseiten. Unsere Kunden schätzen unsere Technologie-Kompetenz, unsere weitsichtige, solide Arbeitsweise und die persönliche Atmosphäre.
UNSER URSPRUNG
2009 standen wir, nach den Gründerjahren der BUCS IT und damals noch mit nur vier Mitarbeitern, vor einer entscheidenden Frage: „Wie können wir mit Spaß und Leidenschaft weiter wachsen?“. Ziel war es, eine langfristige, auf Wachstum ausgelegte Lösung zu schaffen. Im folgenden Jahr erfanden wir uns neu, teilten die Arbeit auf drei Geschäftsführer auf, gründeten die BUCS IT GmbH und konzentrierten unser IT-Dienstleistungsangebot noch mehr auf die Bedürfnisse mittelständischer Unternehmen. Wir wachsen stetig und aus eigenen finanziellen Mitteln. Seit der Umstellung konnten wir im Schnitt jedes Jahr um 42% wachsen und sind heute über 35 Mitarbeiter (Stand August 2015).
UNSERE ZUKUNFT
Heute arbeiten wir mit kleinen Teams, die sich um einen festen Kundenstamm kümmern. So können wir starke persönliche Beziehungen im Team und zu den Kunden aufbauen und pflegen. Die Struktur ist speziell auf mittelständische Kunden ausgelegt. Für organisches Wachstum haben wir uns von dem Prinzip der Zellteilung inspirieren lassen: Wenn ein Team zu groß wird, teilt es sich in zwei neue Teams. Dadurch können wir trotz Wachstum unserer Unternehmensphilosophie treu bleiben und Kunden dauerhaft eine persönliche Betreuung durch feste Ansprechpartner bieten.
- Network Systems
- Network Systems | Network Applications | Networks
- Network Systems
- Network Systems | Network Technologies | Network Structure
- Network Systems | Network Technologies | Network Cabling
- Network Systems
- Network Systems | Network Technologies | Data Network Technology
- Network Systems | Network Technologies | Data Network Technology
- Network Systems
- Network Systems
- Network Systems | Network Technologies | Network Administration
- Network Systems | Computer Networks
- Network Systems
- Network Systems | Data Network Technology | Network Devices
- Network Systems | Network Administration | Network Devices
Network Systems - Manufacturers, Traders & Suppliers

If your company is short of time and needs more information and prices in a timely manner, please use the special service form on our result's page.
Our consultants will find for you the best manufacturers, distributors or service providers for Network Systems and will forward your mail request to these companies immediately.
Are you looking for Network Systems?
Are you looking for Network Systems. IndustryStock's product and service search engine will not only help you find relevant results for Network Systems but also related products and services. All contact information of listed Network Systems manufacturers, traders, suppliers and dealers are freely available to all users.
How do you rate the information on this page?